an ISO 9001:2015 Registered Company
1966-67 Chevrolet Nova
Control Panel Kit
(473271)
(473272)
OFF
DEF
HOT
HI
FLR
DASH
COLD
18865 Goll St. San Antonio, TX 78266
Phone: 800-862-6658
Sales:
[email protected]
Tech Support:
[email protected]
www.vintageair.com
901406 REV C 10/08/21, PG 1 OF 13
www.vintageair.com
Table of Contents
Cover.................................................................................................................................. 1
Table of Contents................................................................................................................. 2
Packing List (473271)/Parts Disclaimer.................................................................................... 3
Packing List (473272)/Parts Disclaimer.................................................................................... 4
OEM Control Panel................................................................................................................ 5
Control Panel Installation....................................................................................................... 6
Final Steps.......................................................................................................................... 7
Control Panel Calibration Procedure........................................................................................ 8
Control Panel Calibration Procedure (Cont.)............................................................................. 9
Wiring Diagram.................................................................................................................... 10
Operation of Controls............................................................................................................ 11
Packing List (473271)........................................................................................................... 12
Packing List (473272)............................................................................................................13
Important Notice—Please Read
Forcontrol
Maximum
Performance,
Air Recommends
This
panel isSystem
designed to
only work with aVintage
Gen IV evaporator
unit equipped the
with Following:
a 246204-PUA
ECU. Please confirm that your unit has the proper ECU prior to installing the control panel as shown
Service
Info:
below.
A replacement
ECU can be purchased from Vintage Air if needed.
Evacuate the system for 35-45 minutes with system components (Drier, compressor, evaporator and
condenser) at a temperature of at least 85° F. On a cool day, the components can be heated with a
heat gun _
OR by running the engine with the heater on before evacuating. Leak check and charge to
specifications.
The Proper Amount of Refrigerant is Critical to Proper System Operation.
Vintage Air Recommends Our System be Charged by Weight with a Quality
Charging Station or Scale.
Refrigerant Capacity for Vintage Air Systems:
(For other systems, consult manufacturer’s guidelines)
R134a System
Charge with 1.8 lbs. (1 lb., 12 oz.) of refrigerant.
Lubricant Capacities:
New Compressor—No Additional Oil Needed.
Used Compessor—Consult Vintage Air.
2
901406 REV C 10/08/21, PG 2 OF 13
Packing List: (473271)
Machined Finish Control Panel Kit
www.vintageair.com
No.
1.
2.
3.
4.
5.
6.
Description
Control Panel Assembly, Machined Finish
Gen IV Universal Control Harness
Nut, 1/4-20, Hex
Screw, 1/4-20 x 3/4”, Pan Head
Spacer, Control Panel
Ground Wire
Part No.
473269
232007-VUR
180054
180053
647011
231520
Qty.
1
1
2
2
1
1
** Before beginning installation, open all packages and check contents of shipment.
Please report any shortages directly to Vintage Air within 15 days. After 15 days,
Vintage Air will not be responsible for missing or damaged items.
HI
OFF
1
DEF
HO T
FLR
2
DAS H
COLD
3
4
5
6
NOTE: Images may not depict actual parts and quantities.
Refer to packing list for actual parts and quantities.
3
901406 REV C 10/08/21, PG 3 OF 13
Packing List: (473272)
Black Anodized Control Panel Kit
www.vintageair.com
No.
1.
2.
3.
4.
5.
6.
Description
Control Panel Assembly, Black Anodized
Gen IV Universal Control Harness
Nut, 1/4-20, Hex
Screw, 1/4-20 x 3/4”, Pan Head
Spacer, Control Panel
Ground Wire
Part No.
473270
232007-VUR
180054
180053
647011
231520
Qty.
1
1
2
2
1
1
** Before beginning installation, open all packages and check contents of shipment.
Please report any shortages directly to Vintage Air within 15 days. After 15 days,
Vintage Air will not be responsible for missing or damaged items.
HI
OFF
1
DEF
HO T
FLR
2
DAS H
COLD
4
3
5
6
NOTE: Images may not depict actual parts and quantities.
Refer to packing list for actual parts and quantities.
4
901406 REV C 10/08/21, PG 4 OF 13
OEM Control Panel
www.vintageair.com
Perform the Following:
1. Remove the (2) OEM mounting screws from the bottom of the dash (discard screws) (See Figure 1, below).
2. Disconnect the cables and wires from the back of the control panel.
3. Remove the control panel.
1966-67 Chevrolet Nova
with A/C Shown
1966-67 Chevrolet Nova
without A/C Shown
FAN
INSIDE
COLD
HI
OEM Blower
Switch Will
Not Be Used
OFF
AIR
TEMPERATURE
DEFROSTER
OUTSIDE
OFF
HOT
COLD
DE-ICE
OFF
Remove
Control Panel
OEM
Screws
AIR
FAN
TEMPERATURE
DEFROST
ON
HOT
DE-ICE
OEM
Screws
Figure 1
5
901406 REV C 10/08/21, PG 5 OF 13
Control Panel Installation
www.vintageair.com
1. Position the spacer into the dash support channel (See Figure 1, below).
2. From behind the dash, place the control panel against the dash opening (See Figure 2, below).
3. While pressing the bezel firmly into the dash aperture, secure the control panel to the dash using (2) 1/4-20 x
3/4” pan head screws and (2) 1/4-20 hex nuts (See Figure 3, below).
4. Plug the control harness into the back of the control panel as shown in Figure 4, below.
Control
Panel
Control Panel
Spacer
Dash Support
Channel
Figure 1
Figure 2
(2) 1/4-20
Hex Nuts
Control
Panel
OFF
HI
DEF
DASH
HOT
COLD
Figure 3
(2) 1/4-20 x 3/4”
Pan Head Screws
NOTE: When using a Vintage
Air supplied control panel,
connect the tan wire from
the Gen IV Evaporator wiring
harness (232600-VUA) to the
factory dash lights to enable
panel backlighting.
Plug Control Harness
into Control Panel
Figure 4
6
901406 REV C 10/08/21, PG 6 OF 13
Final Steps
www.vintageair.com
1. Plug the other end of the control harness into the ECU as shown in Figure 1, below.
ECU
Control
Harness
Figure 1
7
901406 REV C 10/08/21, PG 7 OF 13
Control Panel
Calibration Procedure
www.vintageair.com
On Vintage Air Gen IV systems using cable converters or replacement electronic controls, it is necessary to calibrate
the system to your specific control panel. This procedure ensures that the stroke of your control panel levers or
knobs is translated into precise control of the fan speed, temperature blend and mode door position. Please carefully
read and understand these procedures before beginning. The procedure may be repeated as many times as
necessary to get it right.
In preparation for calibration, you will need to attach the supplied white ground jumper wire to a suitable chassis
ground. This jumper wire must be easily connected to the gray programming wire located in the main Gen IV wiring
harness next to the compressor relay. During the calibration procedure, you will connect the white jumper to the
gray program wire, which will “teach” the Gen IV ECU the upper limits of the control levers or knobs. The blower
will momentarily change speeds, signaling that the upper limits have been “learned”. You will move the levers or
knobs to opposite extreme positions of their travel and then disconnect the white jumper. The blower will again
change speeds, signaling that the lower limits have been learned and that the calibration procedure is complete.
White Jumper
Cable
Gray
Program Wire
8
901406 REV C 10/08/21, PG 8 OF 13
www.vintageair.com
Control Panel
Calibration Procedure (Cont.)
OFF
N
O
START
1. Turn on the ignition switch (Do not start the engine).
OFF
2. Move the control levers/knobs to the positions
shown.
DEF
HI
FLR
DASH
HOT
COLD
OFF
HI
3. Connect the white jumper wire to the gray program
wire. Wait for the blower speed to change (Approximately
5 seconds).
4. Move the control levers/knobs to the positions
shown.
DEF
HOT
FLR
DASH
COLD
5. Disconnect the white jumper wire from the gray
program wire. The blower speed will change,
indicating completion of the calibration procedure.
6. Confirm proper operation of controls. Repeat
procedure if necessary. When finished, tape
over program wire connector with electrical tape to
prevent accidental contact with chassis ground.
9
901406 REV C 10/08/21, PG 9 OF 13
Wiring Diagram
www.vintageair.com
232007-VUR
TAN
ORA
BLK
WHT
JF8
RED
WHT/RED
WHT/YEL
WHT/GRN
AC ANNUNCIATOR
BACKLIGHT POS
BACKLIGHT NEG
GND
5V-SW
TEMP WIPER
MODE WIPER
FAN WIPER
PRE-WIRED
VIEWED FROM WIRE SIDE
232002-VUA
A/C
(IF USED)
GEN IV ECU
GEN IV WIRING DIAGRAM
REV E, 10/6/2017
TEMP
MODE
FAN
PROGRAM
* DASH LAMP
(IF USED)
*** WIDE OPEN
THROTTLE
SWITCH
(OPTIONAL)
** CIRCUIT
BREAKER
30 AMP
HEATER
CONTROL VALVE
* Dash lamp is used only with type 232007-VUR harness.
** Warning: Always mount circuit breaker as close to the battery as possible. (NOTE: Wire between
battery and circuit breaker is unprotected and should be carefully routed to avoid a short
circuit).
*** Wide open throttle switch contacts close only at full throttle, which disables A/C
compressor.
10
901406 REV C 10/08/21, PG 10 OF 13
Operation of Controls
www.vintageair.com
On Gen IV systems with three lever/knob controls, the temperature control toggles between heat and A/C
operations. To activate A/C, move the temperature lever/knob all the way to cold and then back it off to the desired
vent temperature. For heat operation, move the temperature lever/knob all the way to hot and then adjust to the
desired vent temperature. The blower will momentarily change speed, each time you toggle between operations, to
indicate the change. NOTE: For proper control panel function, refer to Pages 8 and 9 for calibration
procedure.
Blower Speed
This lever/knob controls
blower speed, from
OFF to HI.
Mode Control
This lever/knob controls
the mode positions,
from DASH to FLOOR
to DEFROST, with a
blend in between.
Blower
Speed
Mode
Control
Temperature Control
This lever/knob controls
the temperature,
from HOT to COLD.
OFF
DEF
HI
FLR
DASH
COLD
HOT
Temperature
Control
A/C Operation
Blower Speed
Adjust to desired
speed.
Mode Control
Adjust to desired
mode position
(DASH position
recommended).
Temperature Control
For A/C operation, adjust to
coldest position to engage
compressor (Adjust between
HOT and COLD to reach
desired temperature).
OFF
DEF
HI
FLR
DASH
HOT
COLD
OFF
HI
Heat Operation
Blower Speed
Adjust to desired
speed.
Mode Control
Adjust to desired
mode position
(FLOOR position
recommended).
Temperature Control
For maximum heating, adjust
to hottest position (Adjust
between HOT and COLD to
reach desired temperature).
DEF
FLR
DASH
HOT
COLD
OFF
HI
Defrost/De-fog Operation
Blower Speed
Adjust to desired
speed.
Temperature Control
Adjust to desired
temperature.
Mode Control
Adjust to DEFROST position for maximum defrost, or
between FLOOR and DEFROST positions for a bi-level
blend (Compressor is automatically engaged).
11
DEF
HOT
FLR
DASH
COLD
901406 REV C 10/08/21, PG 11 OF 13
Packing List:
Control Panel Kit (473271)
www.vintageair.com
Description
Control Panel Assembly, Machined Finish
Gen IV Universal Control Harness
Nut, 1/4-20, Hex
Screw, 1/4-20 x 3/4”, Pan Head
Spacer, Control Panel
Ground Wire
Part No.
473269
232007-VUR
180054
180053
647011
231520
Qty.
1
1
2
2
1
1
No.
1.
2.
3.
4.
5.
6.
Checked By:
Packed By:
Date:
HI
OFF
DEF
1
HO T
FLR
DAS H
2
COLD
3
4
5
6
12
901406 REV C 10/08/21, PG 12 OF 13
Packing List:
Control Panel Kit (473272)
www.vintageair.com
Part No.
473270
232007-VUR
180054
180053
647011
231520
Qty.
1
1
2
2
1
1
No.
1.
2.
3.
4.
5.
6.
Description
Control Panel Assembly, Black Anodized
Gen IV Universal Control Harness
Nut, 1/4-20, Hex
Screw, 1/4-20 x 3/4”, Pan Head
Spacer, Control Panel
Ground Wire
Checked By:
Packed By:
Date:
HI
OFF
DEF
1
HO T
FLR
DAS H
2
COLD
3
4
5
6
13