Official Software
Get notified when we add a new HondaOther Model Manual

We cover 60 Honda vehicles, were you looking for one of these?

2001-2006--Honda--Odyssey--6 Cylinders 3.5L FI SOHC--32980301
2007-2008--Honda--Civic SI--4 Cylinders 2.0L FI DOHC--33138301
Honda Civic Workshop Manual (L4-1.8L (2006))
Honda - Civic - Wiring Diagram - 2001 - 2003
Honda - Element EX - Wiring Diagram - 2003 - 2004
Honda - Civic - Repair Guide - 2001 - 2006
Honda - Stream - Workshop Manual - 2008 - 2008
Honda - Accord - Workshop Manualre - 2005 - 2010
Honda Accord Workshop Manual (L4-2.4L (2005))
Civic L4-1668cc 1.7L SOHC MFI (2003)
Honda - Prelude - Wiring Diagram - 1997 - 1997
Honda - Odyssey - Wiring Diagram - 2003 - 2003
Honda Civic Workshop Manual (L4-1.3L Hybrid (2008))
Honda Odyssey Lx Workshop Manual (V6-3.5L (2000))
Honda Insight Workshop Manual (L3-1.0L Hybrid (2000))
Honda - Civic - Workshop Manual - 1996 - 2000
2007-2008--Honda--Civic EX--4 Cylinders 1.8L FI SOHC--33247101
2007-2008--Honda--Civic LX--4 Cylinders 1.8L FI SOHC--33247201
Element 2WD L4-2.4L (2003)
2000 2001--Honda--Accord LX--4 Cylinders 2.4L FI DOHC--32980001
2007 Honda Element EX Service Repair Manual
Civic DX Sedan L4-1668cc 1.7L SOHC MFI (2001)
Acura Integra (rs Ls) Workshop Manual ((RS, L4-1834cc 1.8L DOHC PFI (1995))
Honda Odyssey Workshop Manual (V6-3.5L (2003))
Honda Honda Civic Honda Civic 2006 Service Repair Manual
Honda Civic Ex Sedan Workshop Manual (L4-1668cc 1.7L SOHC (VTEC) MFI (2001))
2007-2008--Honda--Odyssey--6 Cylinders 3.5L FI SOHC--33120401
2007-2008--Honda--Civic EX--4 Cylinders 1.8L FI SOHC--33120201
Honda Civic Si Workshop Manual (L4-2.0L (2004))
Honda Crx Si Workshop Manual (L4-1590cc 1.6L SOHC (D16A6) MFI (1988))
Honda Odyssey Workshop Manual (L4-2.2L SOHC (1995))
Honda Civic Workshop Manual (L4-1.8L CNG (2008))
Honda - CRX - Wiring Diagram - 1985 - 1987
Honda Civic Sedan Workshop Manual (L4-1.5L SOHC (16 valve) (1995))
2000 2001--Honda--Civic LX--4 Cylinders 1.7L FI SOHC--32947501
Acura Legend Sedan Workshop Manual (V6-2494cc 2.5L SOHC FI (1987))
Honda Civic Hatchback Workshop Manual (L4-1493cc 1.5L SOHC (D15B1) TBI (1990))
2007-2008--Honda--Civic LX--4 Cylinders 1.8L FI SOHC--33120301
Honda Accord Workshop Manual (V6-3.0L (2003))
Honda Civic Vp Sedan Workshop Manual (L4-1590cc 1.6L SOHC MFI (1999))
2007-2008--Honda--Civic SI--4 Cylinders 2.0L FI DOHC--33247301
Honda Civic Hatchback Workshop Manual (L4-1342cc 1.3L SOHC (EV1) 3V Carb (1986))
Odyssey LX V6-3.5L (2000)
Honda Accord Ex Sedan Workshop Manual (L4-2254cc 2.3L SOHC (VTEC) MFI (1998))
Honda Civic Lx Sedan Workshop Manual (L4-1590cc 1.6L SOHC MFI (1998))
Honda Civic Sedan Workshop Manual (L4-1.6L SOHC (VTEC) (1996))
Honda Odyssey Ex Workshop Manual (L4-2156cc 2.2L SOHC MFI (F22B6) (1997))
Honda - Auto - honda-legend-2006-73413
Honda - Civic EX - Wiring Diagram - 2003 - 2004
2000 2001--Honda--Civic LX--4 Cylinders 1.8L FI SOHC--33051401
Honda - Auto - honda-civic-hatchback-2018-manuel-du-proprietaire-110725
Honda - Odyssey - Workshop Manual - 2005 - 2010
Honda - Auto - honda-civic-2012-5d-73408
Prelude L4-2157cc 2.2L DOHC (VTEC) MFI (2001)
Honda - Prelude - Wiring Diagram - 1987 - 1987
Honda - S2000 - Workshop Manual - 2000 - 2003
Honda Civic Hatchback Workshop Manual (L4-1493cc 1.5L SOHC (D15B2) TBI (1988))
Honda - Civic - Wiring Diagram - (2019)
Honda - Accord - Workshop Manual - 2001 - 2001 (2)
Honda Prelude Workshop Manual (L4-1958cc SOHC (1988))
Summary of Content
Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EB3000 and EB4000 generators. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation. No part of this publication may be reproduced without written permission. This manual should be considered a permanent part of the generator and remain with the generator when sold. Pay special attention to statements preceded by the following B Indicates a strong possibility life if instructions are not followed. CAUTION: instructions NOTE: Indicates a possibility are not followed. words: of severe personal injury or loss of of personal injury or equipment damage if Gives helpful information. If a problem should arise, or if you have any questions about the generator, consult an authorized Honda dealer. B The Honda generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage. CONTENTS CONTENTS 1. GENERATOR SAFETY .. .: ............................... ............................ 2. COMPONENT IDENTIFICATION 3. PRE-OPERATION CHECK ................................. 4. STARTING THE ENGINE .................................. 5. GENERATOR USE ....................................... 6. STOPPING THE ENGINE .................................. 7.MAlNTENANCE ......................................... ............................... 8. TRANSPORTING/STORAGE .................................... 9. TROUBLESHOOTING ........................................ 10. SPECIFICATIONS ....................................... Il. WIRING DIAGRAM 12. HANGER KIT INSTALLATION .................................. 1 2 4 8 11 13 16 24 26 29 30 31 1. GENERATOR SAFETY To ensure safe operation l l l l l l l Place the generator at least 1 m (3 ft) away from buildings or other equipment when operating the generator. Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation. Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instructions. Keep children and pets away from the generator when it is in operation. Keep away from rotating parts while the generator is running. The generator is a potential source of electrical shocks when misued; do not operate with wet hands. Do not operate the generator in rain or snow and do not let it get wet. 2. COMPONENT IDENTIFICATION AUTO ENGINE SWITCH THROTTLE SWITCH \ CIRCUIT BREAKERS \ FUEL VALVE FUEL FILTER VOLTAGE SELECTOR SWITCH RECPTACLES OUNO TERMINAL RECOIL SThRTER GRIP ENGINE I ENGINE 2 OIL DRAIN OIL FILLER PLUG CAP FUEL TANK SPARK CAP \ PLUG COVER / I AIR CLEANER MUFFLER 3 3. PRE-OPERATION CAUTION: stopped. CHECK Be sure to check the generator on a level surface with the engine 1. Check the engine oil level, CAUTION: Engine oil is major factor affecting engine performance service life. Non-detergent or vegetable oils are not recommended. and Use Honda 4-stroke oil, or an equivalent high detergent, premium quality motor oil certified to meet or exceed U.S. automobile manufacturer’s requirements for Service Classification SE or SF. (Motor oils classified SE or SF will show this designation on the container.) SAE low-40 is recommended for general, all-temperature use. If single viscosity oil is used, select the appropriate viscosity for the average temperature in your area. Remove the oil filler cap and check the oil level. If the level is low, fill to the top of the oil filler neck with the recommended oil. CAUTION: Running engine damage. the engine with insufficient oil can cause serious NOTE: When the oil runs lower than the specified level during operation, the engine switch automatically turns off through an oil alert system to protect the engine from overheating. If this occurs, add oil to the top of the filler hole neck, then turn the switch on and restart the engine according to the instructions. ENGINE SWITCH Cont’d 5 2. Check the fuel level. Use automotive gasoline with a research octane of 91 or higher or a pump octane of 86 or higher. Never use an oil/gasoline mixture or water in the fuel tank. or dirty gasoline. Avoid getting dirt, dust CAUTION: Gasoline substitutes are not harmful to the fuel system components. recommended; they may be Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the generator is refueled or where gasoline is stored. Do not overfill the tank and make sure the filler cap is securely closed after refueling. Be careful not to spill fuel when refueling. Fuel vapor or spilled fuel may ignite. If any fuel is spilled, make sure the area is dry before starting the engine. FUEL 6 TANK CAP 3. Make sure that the AC circuit breakers are OFF. The generator may be hard to start if a load is connected. CIRCUIT BRhAKERS 7 4. STARTING THE ENGINE 1. Turn the fuel valve on. FUEL , 2. Pull the choke rod to CLOSE. CHOKE ROD 8 VALVE 3* Make Sure the auto-throttle warm up. AUTO-THROTTLE SWITCH switch is off, or more time will be required for - 4. Turn the engine switch on. ENGfNE SWITCH \ 9 5. Pull the starter grip until compression is felt, then pull briskly. NOTE: hand. Do not allow the starter grip to snap back. Return it slowly by STARTER GRIP 6. Push the choke rod to OPEN as the engine warms up. CHOKE ROD 7. If auto-throttle will be used, turn the switch to “AUTO” has warmed up. 10 after the engine 5. GENERATOR USE m To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground terminal and the ground source. CAUTION: Limit operation requiring maximum power (EB3000 : 3.0 kVA, EB4000 : 4.0 kVA) to 30 minutes. For continuous operation, do not exceed the rated power of 2.8 kVA (EB3000) and 3.8 kVA (EB4000). In either case, the total wattage of all appliances connected must be considered. l Do not exceed the current limit specified for any one receptacle. l Do not connect the generator to a household circuit. This could cause damage to the generator or to electrical appliances in the house. l Auto-throttle system With the switch in the AUTO position, engine speed is automatically reduced to an idle when all loads are turned off or disconnected. When appliances are turned on or reconnected, the engine resumes the rated speed. At OFF, the auto-throttle system does not operate. NOTE: AUTO is recommended to minimize fuel consumption. l The auto-throttle system will not respond to electrical loads of less than 1 ampere. l The system is not effective for use with appliance that require only momentary power. To avoid extended warm-up periods, keep the switch OFF until the engine reaches operating temperature. l 11 AC applications 1. Turn the voltage selector switch to either position as required. When the switch is turned to “12OV ONLY” position, you can use only 12OV AC. At “12OV/24OV” position, you can use both 12OV and 240V sources. 2. Switch on the AC Circuit Breakers. 3. Plug in the appliance. NOTE: This generator is equipped Regulator) for stable voltage supply. with an AVR (Automatic Voltage CAUTION: Be sure that appliances do not exceed the rated load for more than 30 minutes, and never exceed the maximum load. Substantial overloading will switch off the circuit breaker. Lesser overloading will not switch off the circuit breaker and will shorten the service life of the generator. 12 6. STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch OFF. In normal use: 1. Turn the AC circuit breakers OFF. 2. Turn the engine switch OFF. ENGINE SWITCH 13 3. Turn the fuel valve OFF. FUEL 14 VALVE 7. MAINTENANCE The purpose of the maintenance schedule and adjustment generator in the best operating condition. Inspect or service as scheduled in the table on the next page. is to keep the M Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas. CAUTION: Use only genuine HONDA parts or their equivalent. The use of replacement parts which are not of equivalent quality may damage the generator. 15 Maintenance Schedule REGULAR SERVICE 3 months Inspection 6 months year 0 Engine oil Change Inspection Air cleaner element Fuel filter Cleaning 0 0 0 0 (1) cleaning 0 Spark plug maintenance Valve clearance 0 0 (2) adjustment Combustion chamber valve cleaning and 0 (2) Fuel line inspection (Replace if necessary) Spark arrester NOTE (1) : Service more frequently 0 Clean every 100 operating when used in dusty areas. .(2) : These items should be serviced by an authorized owner has the proper tools and is mechanically Shop Manual. 16 hours. Honda dealer, unless the proficient. See the Honda Tool kit The tools supplied are necessary for performing simple adjustments and repairs. Always keep the kit with the generator. some periodic maintenance, Changing oil Drain the oil while the engine is still warm to assure rapid and complete draining. 1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug securely. 2. Refill with the recommended oil (see page 4) and check the level. OIL FILLER CAP 47 Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly (page 16). Service more frequently when operating the generator in extremely dusty areas. m Never use gasoline or low flash point solvents for cleaning cleaner element. A fire or explosion could result. CAUTION: Never run the generator without wear may result. the air the air cleaner. Rapid engine 1. Unsnap the clips, remove the air cleaner cover and remove the element. ELEMENT 2. Wash the element in a non-flammable or high flash point solvent and dry it thoroughly. 3. Soak the element in clean engine oil and squeeze out the excess oil. 4. Reinstall the air cleaner element and the cover. ELEMENT 19 Fuel filter service The filter prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the filter should be cleaned. 1. Turn the fuel valve OFF. Remove the filter cup. 2. Clean the cup thoroughly. 3. Reassemble. Do not damage the rubber gasket. m After installing the filter cup, check for fuel leaks and make sure the area is dry before starting the engine. FUEL VALVE Spark plug service Recommended spark plug: BR4HS (NGK) W14FSR-U (ND) To ensure proper engine operation, and free of deposits. the spark plug must be properly gapped 1. Remove the spark plug cover. 2. Clean any dirt from around the spark plug base. 3. Remove the spark plug cap. SPARK PLUG COVER PLUG CAP 27 4. Use the wrench supplied in the tool kit to remove the spark plug. 5. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. 6. Measure the plug gap with a feeler gauge. The gap should be 0.6-0.7 mm (0.024-0.028 in). Correct as necessary by bending the side electrode. 7. Attach the plug washer. Thread the plug in by hand to prevent cross-threading. 8. Tighten a new spark plug l/2 turn with the wrench to compress the washer. If you are reusing a plug, it should only take l/8-1/4 turn after the plug seats. CAUTION: l The spark plug must be securely tightened. An improperly can become very hot and possibly damage the generator. l Never use a spark plug with an improper heat range. 1 tightened plug PLUG GAP f 0.6-0.7 mm (0.024-0.028 in) PLUG WRENCH 22 N !=- I Spark arrester maintenance bxw If the generator has been running, Allow it to cool before proceeding. the muffler will be very hot. CAUTION: The spark arrester must be serviced every 100 hours to maintain its efficiency. 1. 2. 3. 4. Loosen the bolts and nuts and remove the muffler. Loosen two 8 mm bolts to remove the exhaust pipe. Check the muffler exhaust port for carbon deposits; clean if necessary. Remove the spark arrester from the muffler. Clean the screen and inspect it for damage. Replace if necessary. 5. Install the spark arrester in the muffler. Install the muffler and gasket and tighten the bolts and nuts securely. m NUTS MUFFLER / PROTECTOR V EXHAUST PIPE MUFFLER SPARK’ARRESTER 6 mm BOLTS 8 mm BOLTS 23 8. TRANSPORTING/STORAGE m When transporting the generator, turn the engine switch OFF and keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust. 2. Drain the fuel a. With the fuel valve OFF, remove and empty the filter cup. b. Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container. c. Replace the filter cup and tighten securely. FI’iTER 24 CUP d. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. DRAIN SCREW e. Pull the starter grip until resistance is felt; the piston is coming up on its compression stroke. At this position, the exhaust and intake valves are closed, and this will help protect the engine from corrosion. STARTER GRIP’ 25 9. TROUBLESHOOTING A. When the engine will not start: 1, Is there enough fuel? 2. Is the fuel valve on? 3. Is gasoline reaching the carburetor? To check, loosen the drain screw with the fuel valve on. h-1 If any fuel is spilled, make sure the area is dry before testing the spark plug or starting the engine. Fuel vapor or spilled fuel may ignite. DRAIN SCREW I 4. Is there enough oil in the crankcase? 5. Is the AC circuit breaker off and nothing terminals? 6. Is the engine switch on? 7. Is there a spark at the spark plug (page 27)? 26 connected to the DC a. Remove the spark plug cover and cap. Clean any dirt form around the spark plug base, then remove the spark plug. b. Install the spark plug in the plug cap. c. Turn the engine switch on. d. Grounding the side electrode to the stay, pull the recoil starter to see if sparks jump across the gap. GROUNDING STAY - ENGINE SWITCH STARTER GRIP e. If there are no sparks, replace the plug. If OK, try to start the engine according to the instructions. 8. If the engine still does not start, take the generator to the dealer. 27 B. When the engine starts but stops immediately: Is there enough oil in the crankcase? If not, the engine switch will turn off after starting. C. No electricity at the AC receptacles: 1. Is the AC circuit breaker on? 2. Check the electrical appliance or equipment 28 for any defects. 10. SPECIFICATIONS Dimensions EB3000 : 605 x 425 x 620 mm (23.8 x 16.7 x 24.4 in) EB4000 : 650 x 425 x 650 mm (25.6 x 16.7 x 25.6 in) EB3000 : 64.5 kg (142.2 lb), EB4000 : 81.5 kg (179.7 lb) Length x Width x Height Dry weight Engine Honda G E300 Model Engine Type Displacement [Bore x Stroke1 Compression Ratio Engine Speed Cooling System Ignition System Oil Capacity Fuel Tank Capacity Spark Plug I Honda G E400 4Stroke, side valve, 1 cylinder 272 cm3 (16.6 cu in) 1 406 cm3 (24.8 cu in) [86x70mm (3.4x2.8 in)] [76x60mm (3.0x2.4 in)] 6.8 : 1 6.5 : 1 3,600 rpm Forced air cooling Flywheel magneto 1.2 1.2 liter Q (5.1(1.3 us US qt) qt) 16.5 Q (4.4 US gal) BR4HS (NGK) W14FSR-U (ND) Generator Rated voltage Rated frequency Rated ampere AC output Rated output Maximum output 120 VI240 V 60 Hz EB3000 : 23.5/l 2A EB4000 : 32/16A EB3000 : 2.8 kVA (2800 EB4000 : 3.8 kVA (3800 EB3000 : 3.0 kVA (3000 EB4000 : 4.0 kVA (4000 WI W) W) W) 29 GLNtRATOR ---------------------~ i I CONTROL r- ----- BOX ------------- KM CONTROL VALVE I IZOV/ZUIV-1 I t -12OV ----- ONLY WH,TE LIGHT ......... w Lg ......... BLACK GREEN RED ......... ......... ......... e G R ---------- GREEN GROUND TERMINAL ____ , , 12. 6 mm BOLT CAUTION: HANGER KIT INSTALLATION HANGER I Be sure to set the hanger at the position as illustrated below. HANGER i / SPARK PLUG COVER FUEt J\ TANK CAP 31 Current customer service contact information: United States, Puerto Rico, and U.S. Virgin Islands: Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership's management. The Service Manager or General Manager can help. Almost all problems are solved in this way. If you are dissatisfied with the decision made by the dealership's management, contact the Honda Power Equipment Customer Relations Office. You can write: American Honda Motor Co., Inc. Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta, GA 30005-8847 Or telephone: (770) 497-6400 M-F, 8:30 am - 7:00 pm EST When you write or call, please provide the following information: • Model and serial numbers • Name of the dealer who sold the Honda power equipment to you • Name and address of the dealer who services your equipment • Date of purchase • Your name, address, and telephone number • A detailed description of the problem 32 MEMO 33 MEMO 34